نوکریاں ٹینڈرز کمپنیاں پیکجز پلیٹ فارمز یہ کیسے کام کرتا ہے۔ ہمارے بارے میں رابطہ کریں۔
نوکری پوسٹ کریں۔ لاگ ان کریں۔
J
نوکری معاہدہ

Data Centre Commissioning Engineer

Narvik, Norge Ingeniørfag Publisert 8. ستمبر 2026

Om stillingen

Data Centre Commissioning Engineers – Electrical and Mechanical

Location: Narvik, Norway

Contract length: Nine months

Rotation: Two weeks on / one week off

Working schedule: Six days per week, ten paid hours per day

Start date: ASAP

Role overview

We are recruiting Electrical and Mechanical Commissioning Engineers for a major data-centre construction project in Narvik, Norway.

These are initial nine-month contracts supporting the commissioning, testing and handover of mission-critical electrical and mechanical infrastructure. Contractors will work on a two-weeks-on, one-week-off rotation, completing six ten-hour shifts during each working week.

Direct data-centre commissioning experience is required. Candidates must have previously supported the testing and commissioning of critical electrical or mechanical systems through relevant commissioning stages.

Position 1: Electrical Commissioning Engineer

The Electrical Commissioning Engineer will support the inspection, testing, energisation and functional verification of critical electrical systems throughout the data-centre commissioning programme.

Responsibilities

  • Execute electrical commissioning activities across relevant commissioning levels.
  • Perform pre-functional, functional and integrated systems testing.
  • Test LV electrical distribution systems and associated critical-power equipment.
  • Complete insulation-resistance, continuity, dead and live testing.
  • Support energisation and switching activities.
  • Test switchgear, switchboards, busbars, PDUs and distribution equipment.
  • Support commissioning of UPS systems, battery systems and generators.
  • Verify ATS/STS operation, interlocks, alarms and protection systems.
  • Review electrical schematics, single-line diagrams and commissioning procedures.
  • Identify faults, record defects and coordinate corrective actions and retesting.
  • Complete test sheets, commissioning reports, punch lists and handover documentation.
  • Coordinate with construction teams, vendors, clients and other commissioning disciplines.
  • Follow site safety requirements, including RAMS, LOTO and permit-to-work procedures.

Electrical requirements

  • Previous electrical commissioning experience on data-centre projects.
  • Experience with LV distribution, switchgear and critical-power systems.
  • Knowledge of UPS systems, batteries, generators, PDUs and busbars.
  • Experience conducting insulation-resistance, continuity, dead and live testing.
  • Ability to read electrical schematics and single-line diagrams.
  • Experience preparing and completing commissioning documentation.
  • Strong understanding of electrical safety and energisation procedures.
  • Industrial electricians with substantial data-centre testing and commissioning experience may also be considered.

Position 2: Mechanical Commissioning Engineer

The Mechanical Commissioning Engineer will support the inspection, testing, balancing and functional verification of the data centre’s HVAC and cooling infrastructure.

Responsibilities

  • Execute mechanical commissioning activities across relevant commissioning levels.
  • Perform system walkdowns and verify mechanical completion.
  • Support flushing, pressure testing, cleaning and system preparation.
  • Commission chilled-water systems, pumps, pipework, valves and associated equipment.
  • Support testing of chillers, CRAHs, CRACs, AHUs and ventilation systems.
  • Verify equipment operation against design requirements and sequences of operation.
  • Support TAB, functional performance testing and integrated systems testing.
  • Identify installation or performance issues and coordinate corrective actions.
  • Manage punch items and support retesting through to closure.
  • Review drawings, P&IDs, commissioning procedures and technical documentation.
  • Produce test records, commissioning reports and handover documentation.
  • Coordinate with electrical, BMS, controls, vendor and construction teams.
  • Follow site safety requirements, including RAMS, LOTO and permit-to-work procedures.

Mechanical requirements

  • Previous mechanical commissioning experience on data-centre projects.
  • Experience with mission-critical HVAC and cooling systems.
  • Knowledge of chilled-water systems, pumps, valves and pipework.
  • Experience with chillers, CRAHs, CRACs, AHUs or similar cooling equipment.
  • Experience with flushing, pressure testing, TAB and functional testing.
  • Ability to read mechanical drawings, P&IDs and sequences of operation.
  • Experience supporting integrated systems testing and final handover.
  • Strong commissioning documentation and fault-resolution skills.

Rotation and working hours

  • Two weeks working on-site followed by one week off.
  • Six working days per week while on rotation.
  • Ten paid hours per working day, including the scheduled break.
  • Contractors are paid for hours worked during the on-site rotation.
  • The rotational week off is unpaid.
  • No separate overtime or national-holiday payment structure applies.

Travel and accommodation

  • Flights are arranged and paid for each rotation.
  • Accommodation is provided for the duration of each on-site rotation.
  • Contractors receive their own private bedroom and en-suite bathroom.
  • Kitchen and general living areas are shared with other contractors.
  • Breakfast and dinner are provided.
  • Contractors may prepare lunch using the available breakfast provisions.

Contract requirements

  • Available for an ASAP start or following a reasonable notice period.
  • Willing to work in Narvik on the stated rotation.
  • Eligible to work in Norway under an appropriate arrangement.
  • Comfortable working through an approved payroll provider.
  • Comfortable with mandatory 30-day payment terms and monthly payment in arrears.
  • Able to provide their own laptop.
  • Able to work effectively within a multidisciplinary commissioning team.
  • Professional working proficiency in English.

Application

Please submit an up-to-date CV clearly showing:

  • The data-centre projects on which you have worked.
  • Whether your experience is electrical or mechanical.
  • The commissioning levels and systems you have personally tested.
  • Your current location and work authorisation.
  • Your availability and notice period.
  • Your hourly-rate expectations.
  • Confirmation that you can work the two-weeks-on, one-week-off rotation.